(EN) ISO 52016-3 (adaptive building envel.elements)

Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads  — Part 3: Calculation procedures regarding adaptive building envelope elements

 

ISO Standards catalogue

 

Geographical scope:
Global
Theme:
(EP) Calculation procedures
Published date:
Sept. 15, 2023
Topics:
  • Building as such
Responsibility:
CEN and/or ISO

Abstract

EN ISO 52016-3:2023 specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1, but modified for the situation that the building envelope contains one or more adaptive building envelope elements. These are building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions.

The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1.
The three types of adaptive building envelope elements covered in this document are:

  • Building envelope elements with dynamic solar shading
  • Building envelope elements with chromogenic glazing
  • Building envelope elements with an actively ventilated cavity

Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing.
This document is applicable to the assessment of the energy performance of buildings (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria.

It is also applicable to assess the contribution of the adaptive building envelope element to the smartness readiness of a building.
In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.
This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones.

NOTE 1     The background to the selection of adaptive building envelope elements is given in CEN ISO/TR 52016-4 (under preparation).